<ErrorMessage>
WSCOMM: Image too wide for plate
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The workstation has sent an image that, by the recorder's calculation, is wider than the plate, i.e. along the
drum axis.
</text></DescriptionText>
<DescriptionText><text>
There is a bug in early HRX firmware that can cause this error.  The workaround is to change the "set sys
ism" parameter to 3. No harm can be caused by setting this parameter, even if it doesn't fix the error.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Reload the bay, double checking plate size.  This error may also be caused by a problem with the RIP or
the Postscript file.  Record the plate colour(s) that have this error and call Creo Service if the plate size is
ok.
</text></DescriptionText>
</OperatorAction>
<Cause>
Mismatch between the plate widths entered in the recorder and the workstation
</Cause>
<Cause>
Imposition or RIP error
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sys_cfg_ism.xml</LinkAddress><LinkTitle>NVS: sys ism</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:21 2008 PST
</Updated>
<Links>
</Links>
</Error>